Sovol OrcaSlicer
Sovol OrcaSlicer 2.3.0.4
Scheda ufficiale di Sovol OrcaSlicer 2.3.0.4, pubblicata il 8 set 2025.
Stabile1 pacchetti pubblici6270 download GitHub registrati
File ufficiali di questa release
Windows · 1 file
- SovolSlicer_Windows_Installer_V2.3.0.4.exeNon specificato nel nome del file · 129,2 MiB · 6270 downloadDownload ufficiale ↗
✓ SHA-256 disponibile
Verifica il file
SHA-256 previsto7b71ff161da6515251adb8db59dd7df0ac0e2165628be252509e863b3058ea29Comandi di verifica locale
Windows PowerShellGet-FileHash -Algorithm SHA256 -LiteralPath '.\SovolSlicer_Windows_Installer_V2.3.0.4.exe'Terminale macOSshasum -a 256 -- 'SovolSlicer_Windows_Installer_V2.3.0.4.exe'Terminale Linuxsha256sum -- 'SovolSlicer_Windows_Installer_V2.3.0.4.exe'Il digest è fornito da GitHub per il file dell’editore. Un risultato locale uguale conferma che i byte corrispondono.
Verifica SHA-256 →
Modifiche ai pacchetti dalla release precedente
Rispetto a 2.3.0.2, tutti i conteggi classificati restano invariati con 1 file pubblici.
I conteggi sono viste separate dei nomi file dell’editore per piattaforma, processore e formato. Non garantiscono compatibilità o supporto.
Anteprima delle note
Estratto in testo semplice dalle note dell’editore. Apri la release ufficiale per il testo completo e aggiornato.
Le note dell’editore restano nella lingua originale. Questo estratto non è tradotto automaticamente.
SV08 & SV08 MAX Release Notes
Applicable Models: SV08 / SV08 MAX
🔧 Update Overview
1. Model Configuration Optimization
- Removed SV08PRO-related parameter configurations to focus on SV08 and SV08 MAX models.
2. SV08 Print Start Process Optimization
- Reduced impact of secondary homing on first-layer printing — Improved homing algorithm to minimize interference with first-layer printing height and increase success rate.
- Resolved overvoltage issue caused by startup sequence — Adjusted the heating sequence: heat the bed first, then execute the START_PRINT command to prevent power overload.
3. SV08 MAX Print Logic Fix
- Fixed unresponsiveness after initiating print to ensure immediate task execution.
4. System Process Simplification
- Disabled plugin installation to simplify the initialization process and improve system stability and startup speed.
5. UI Interaction Improvements
- Fixed the top-layer display issue for Sovol machines to enhance user experience.
⚠️ Notes
- This update applies only to SV08 and SV08 MAX models.
- If printing abnormalities occur, check whether the G-Code parameters match the printer model.
SV08 & SV08 MAX 更新说明
适用机型: SV08 / SV08 MAX
🔧 更新内容概览
1. 机型配置优化
- 移除 SV08PRO 相关参数配置,专注 SV08 和 SV08 MAX 机型支持。
2. SV08 打印启动流程优化
- 优化二次归零对首层打印的影响 — 调整归零算法,减少对首层打印高度的干扰,提升打印成功率。
- 解决启动顺序导致的过压问题 — 将加热流程调整为先升温热床,后执行 START_PRINT 指令,避免电源过载。
3. SV08 MAX 打印逻辑修复
- 修复开始打印后无动作响应的问题,确保打印任务立即执行。
4. 系统流程简化
- 关闭插件安装功能,简化初始化流程,提升系统稳定性和启动速度。
5. 界面交互优化
- 修复 Sovol 机器置顶显示问题,提升用户操作体验。
⚠️ 注意事项
- 本次更新仅适用于 SV08 和 SV08 MAX 机型。